mV/A/m cable data sources

Record fields for mV/A/m cable data used in Australian voltage-drop worksheets without publishing controlled cable table values.

  • Cable and voltage · Worksheet fields
  • High-sensitivity table
  • Last checked 13 July 2026

Evidence to capture for mV/A/m cable data

Show which source fields should travel with an entered mV/A/m value without replacing the governing cable data source.

mV/A/m data notes
FieldRecordSourceBoundary
mV/A/m valueEntered voltage-drop data value used by the calculator.Project, product or standards-review sourceThe public table does not publish cable-data values.
Cable labelMetric size, conductor material and cable type tied to the value.Cable schedule or product dataDo not reuse a value across a different cable context.
Installation basisInstallation method, grouping and route context noted with the value.Design note or governing sourceInstallation conditions can change the applicable data.
Temperature basisAmbient or conductor-temperature assumption where the source states it.Source note or project assumptionTemperature correction is not inferred by this table.
Source revisionEdition, datasheet revision or project note date.Document control recordA stale source should be rechecked before reuse.
  • Use this table to make entered cable data traceable.
  • Calculator results are only as strong as the source value entered.

How mV/A/m evidence supports voltage-drop work

Record where the entered mV/A/m value came from so voltage-drop results can be reviewed against the cable family and installation context.

How mV/A/m data should be treated
ItemValue
PurposeShow which source fields should travel with an entered mV/A/m value without replacing the governing cable data source.
How to use the sourceField table only; mV/A/m voltage-drop arithmetic lives on the calculator and formula chart.
Standards and project contextAS/NZS 3008 context noted for project review; verify current source documents before applying entered values.
Where judgement is still neededUse this table for lookup, labelling or worksheet context; do not treat it as a project-specific calculation result.
Before relying on itConfirm current standards, local authority requirements, DNSP conditions, project documents and manufacturer data before relying on a decision.

Project source basis for cable data

Keep the cable data source, checked date and product context visible whenever a calculator uses the entered value.

mV/A/m data notes source basis
ItemValue
SourceAUWiring voltage-drop calculator field model and Australian cable-data record practice.
Source typeProject or product record model
Derivation basisAUWiring field table for sourced cable-data records; no AS/NZS cable table values are reproduced.
Last checked2026-07-13
Review intervalAnnual or when voltage-drop calculator fields, cable-data practice or standards context changes.
Review triggerCalculator field change, cable-data source change, standards update or project feedback.
Version usedR04-2026-07-13
Australian applicationAustralia; project, cable product, installation method, temperature and governing source can change the value used.