Protection, Fault & Earthing
Circuit Breaker Rating Checks
Compare the entered Ib, In, Iz and prospective-fault/device-interrupt-capacity values as separate arithmetic checks without selecting a device or claiming compliance.
Open calculatorReview protection and earthing calculations using entered device data, fault levels, conductor properties, test measurements and soil assumptions. These checks expose margins and modeled values for design review; they do not replace device coordination data, testing procedures or professional verification.
Protection, Fault & Earthing
Compare the entered Ib, In, Iz and prospective-fault/device-interrupt-capacity values as separate arithmetic checks without selecting a device or claiming compliance.
Open calculatorProtection, Fault & Earthing
Compare a downstream prospective fault current with a manufacturer-published selectivity limit for one exact protective-device pair.
Open calculatorProtection, Fault & Earthing
Calculate required conductor area and withstand current from fault current, clearing time and an entered k coefficient.
Open calculatorProtection, Fault & Earthing
Calculate the minimum protective-conductor area, selected-conductor withstand and I²t duty from user-provided fault current, clearing time and k coefficient.
Open calculatorProtection, Fault & Earthing
Estimate line-to-earth loop impedance, temperature-adjusted conductor resistance and fault current from user-entered source and conductor data.
Open calculatorProtection, Fault & Earthing
Estimate the resistance of a single vertical rod in uniform soil using the modified Dwight long-rod approximation and user-entered soil resistivity.
Open calculatorProtection, Fault & Earthing
Convert a required fault current into a maximum loop impedance and route length using entered source and conductor data.
Open calculatorProtection, Fault & Earthing
Estimate neutral RMS duty from fundamental imbalance and aligned third-harmonic current, then compare it with corrected neutral capacity.
Open calculatorProtection, Fault & Earthing
Estimate modeled neutral RMS current from fundamental phase-current imbalance and aligned triplen (third-harmonic) phase currents.
Open calculatorProtection, Fault & Earthing
Estimate the fault current at the end of a source and cable path using source fault level and entered cable impedance.
Open calculatorProtection, Fault & Earthing
Combine a user-entered active-to-earth sizing ratio with an adiabatic fault-duty minimum for a protective conductor.
Open calculatorProtection, Fault & Earthing
Compare a measured RCD/RCBO trip current and time with an entered test multiplier and maximum time.